Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler

Product Details
Customization: Available
Function: Steam Boilers
Fuel: Electric Heating
Still deciding? Get samples of US$ 1858/Piece
Request Sample
Manufacturer/Factory
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
20000000 RMB
Plant Area
>2000 square meters
  • Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
  • Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
  • Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
  • Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
  • Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
  • Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • FAQ
Overview

Basic Info.

Model NO.
JX-ZQ-15
Structure
Fire Tube
Media
Steam
Water Circulation
Forced Circulation
Drum Placement
Vertical Boiler
Pressure
Low Pressure
Usage
Industrial, Home
Rated Current
22A
Rated Steam Temperature
165 Degrees Celsius
Rated Steam Pressure
0.7MPa
Sewage Caliber
4 Points
Steam Outlet Diameter
4 Points
Transport Package
Wooden Frame
Specification
370*900*520
Trademark
Jonson
Origin
Guangdong Province, China
HS Code
8514400090
Production Capacity
800 Pieces / Month

Product Description

Guangdong Jiangxin Electronic Technology Co., Ltd.
 
Main Products:
Induction Heater
Induction heating control board
Induction water heater
Induction hot blast stove
Induction heater coil
Induction Steam Generator
Cabinet type induction heater

 
The traditional steam generator uses ordinary electric heating tubes, which are not used for a long time, and the scale is particularly severe. With the increase of scale, the heating efficiency is getting lower and lower, which is easy to break, which brings great inconvenience to users. Therefore, the electromagnetic steam generator is developed based on the problems of the traditional electric steam generator. Using the principle of high-efficiency electromagnetic induction heating, it not only greatly improves the heating efficiency, but also greatly reduces the scale under the condition of the same water quality, so as to greatly improve the service life.
 

Product Description

With the development of society, energy conservation and environmental protection have gradually become an important issue of concern to all sectors of society and affecting social development. It is imperative to use clean energy such as electricity, solar energy and wind energy to replace fossil fuels.In the actual industrial production process, due to process production requirements, stable, continuous high temperature and high pressure steam is often required. To this end, according to the actual production needs of the existing small steam generator, we launched several environmental protection, efficient, can replace the existing small coal-fired boiler thermal instantaneous steam generator.At present, there are single phase: 8kW/220V, three phases: 12kW/380, 15kW/380, 20kW/380, 30kW/380, 60kW/380. Through combination, 120kW, 240kW, 360kW and 720kW can be achieved.

Why choose an electronmagnetic steam generator 
How is it different from other steam generators
Steam engine type Gas steam generator Resistance type steam generator Coal-fired steam generator Jonson electromagnetic steam generator
Heating medium The fuel gas Heating wire Coal burning Electromagnetic induction
Thermal energy utilization 85% 88% 75% 96%
need someone on duty Need someone to replace gas Unattended Need someone to burn coal Fully automatic machine
Temperature control accuracy (ºC) ±8 ±6 ±15 ±3
heating rate slow Faster slow fast
working environment  clean  clean Dirty, disorderly  clean
Production danger Complicated piping, risk of air leakage Risk of electric leakage Danger of high temperature and heavy pollution Water and electricity separation, never leak electricity
Operational performance complex simple complex simple

Product technical parameters
The project content rated power Rated current Evaporation Thermal efficiency Input voltage Steam outlet diameter The caliber of the safety valve Inlet caliber Sewage caliber Dimensions, length * width * height
unit KW A Kg/h % V/Hz / / / / mm
Pieces 8 36 12 98 220V/50Hz 4 points 4 points 4 points 4 points 370*900*520
Pieces 12KW 18 17 98 380V/50Hz 4 points 4 points 4 points 4 points 370*900*520
Pieces 15KW 22 22 98 380V/50Hz 4 points 4 points 4 points 4 points 370*900*520

Detailed Photos

Automatic industrial commercial electric steam generator Manufacturing Pressure adjustable electromagnetic steam boiler

Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 
Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 
Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 
Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 
Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 
Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 
Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 
Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 
Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 
Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 
Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 
Automatic Industrial Commercial Electric Steam Generator Manufacturing Pressure Adjustable Electromagnetic Steam Boiler
 

FAQ

1.How can I get the price?

-We usually quote within 24 hours after we get your inquiry(Except weekend and holidays).
-If you are very urgent to get the price, please email us or contact us in other ways so that we can offer you a quote.
2. Can I buy samples placing orders?
-Yes.Please feel free to contact us.
3.What is your lead time?
-It depends on the order quantity and the season you place the order.
-Usually we can ship within 7-15 days for small quantity,and about 30 days for large quantity.
4.What is your payment term?
-T/T,Western Union,MoneyGram,and Paypal.This is negotiable.
5.What is the shipping method?
-It could be shipped by sea,by air or by express(EMS,UPS,DHL,TNT,FEDEX and ect).
Please confirm with us before placing orders.
6.How do you make our business long-term and good relationship?
-1. We keep goodquality and competitive price to ensure our customers benefit ;
-2. We respect every customer as our friend and we sincerely do business and make friends with them,no matter where they come from.

 
Why Choose us?
1, The world-famous brand Infineon IGBT inverter module is used to ensure the stability of the product.
2, a High-speed DSP phase-shifting algorithm is used, and each output cycle is precisely calculated to achieve optimal energy-saving purposes.
3, Magnetically isolated drive technology solves the interference problem caused by the optical drive.
4, strong environmental adaptability, can be used in harsh environments;
5, The system control power supply adopts multi-level EMI suppression to ensure the best quality power supply under harsh power supply conditions.
6, strong anti-interference ability, up to more than 50MW combination of parallel work and reliable operation.
7. Coil to ground protection function. When the coil is broken or the coil is shorted to ground, it can effectively protect the whole system and ensure safe use.
8. It can be customized by water cooling and air cooling, and the cooling fan is a high-speed dc fan to protect the controller cooling system
9. The incoming and outgoing wires of the power supply use copper bar structure and pure copper high-current terminals to ensure that the copper bars and terminals do not generate heat when they are overworked.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed