Customization: | Available |
---|---|
Warranty: | 1 Year |
Type: | Induction Heating Machine |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
JS1000 series JS1000-020 (three-phase full-bridge 20KW electromagnetic heater) is our company's special for plastic machinery, food machine Designed for the application of pipeline heating and plane heating equipment such as machinery, aluminum-plastic machines, drum equipment, heating, oil and gas transportation, etc.Designed for the application of pipeline heating and plane heating equipment such as machinery, aluminum-plastic machines, drum equipment, heating, oil and gas transportation, etc.
Name | Performance parameter |
rated power | Three-phase 20KW |
Rated input current | 27-30(A) |
Rated output current | 30-50(A) |
Rated voltage frequency | AC 380V/50Hz-60Hz |
Voltage adaptation range | constant power output at 300 ~ 400V |
Adapt to ambient temperature | -20ºC~50ºC |
Adapt to environmental humidity | ≤95% |
Power adjustment range | 20% ~ 100% stepless adjustment(That is: adjustment between 0.5 ~ 20KW) |
Heat conversion efficiency | ≥95% |
Effective power | ≥98%(Can be customized according to user needs) |
working frequency | 5~40KHz |
Main circuit structure | Full bridge series resonance |
Control System | DSP-based high-speed automatic phase-locking tracking control system |
Application mode | Open application platform |
monitor | Programmable digital display |
start time | <1S |
Instantaneous overcurrent protection time | ≤2US |
Power overload protection | 130% instantaneous protection |
Soft start mode | Fully electrically isolated soft start heating / stop mode |
Support PID adjustment power | Identify 0-5V input voltage |
Support 0 ~ 150 ºC load temperature detection | Accuracy up to ± 1 ºC |
Adaptive coil parameters | 20KW 10 square line, length 60m, inductance 250 ~ 300uH |
Coil to load distance(Thermal insulation thickness) | 20-25mm for circle, 15-20mm for plane, 10-15mm for ellipse and within 10 mm for super ellipse |