High Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction Heater

Product Details
Customization: Available
Warranty: 1 Year
Type: Induction Heating Machine
Manufacturer/Factory
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
20000000 RMB
Plant Area
>2000 square meters
  • High Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction Heater
  • High Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction Heater
  • High Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction Heater
  • High Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction Heater
  • High Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction Heater
  • High Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction Heater
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • FAQ
  • Why Choose us?
Overview

Basic Info.

Model NO.
JS1000-100
Structure
Wall-Mounted
Brand
Jonson
Name
Induction Heater
Rated Power
100kw
Rated Voltage
380V
Power Adjustment Range
20~100%
Operation Temperature
0~600
Adapt to Ambient Temperature
-20 Degrees Celsius to 50 Degrees Celsius
Rated Input Current
120-150(a)
Voltage Adaptation Range
340V~440V
Working Frequency
5~40kHz
Transport Package
Carton
Specification
635mm*445mm*315mm
Trademark
Jonson
Origin
Guangdong Province, China
HS Code
8514400090
Production Capacity
800 Pieces / Month

Product Description

Guangdong Jiangxin Electronic Technology Co., Ltd.
Guangdong Jiangxin Electronic Technology Co., Ltd. is an extraordinary energy-saving solution provider. Its products and solutions are widely used in heating, chemical industry, mold manufacturing, plastic machinery, food processing and other industries. The company has a strong product R & D and engineering technology team, which is committed to transforming wisdom into excellent products and services, meeting the needs of different customers and continuously creating value for customers.and building reliable and stable green energy-saving products and solutions for users are the key to maintaining the advantages of the company.
Main Products:
Induction Heater
Induction heating control board
Induction water heater
Induction hot blast stove
Induction heater coil
Induction Steam Generator
Cabinet type induction heater


Electromagnetic heater installation steps:
Installation and commissioning of electromagnetic heaters: installation and commissioning of electromagnetic heaters is relatively simple
1. Before the transformation, first check the wiring of the equipment, take photos, make marks (in order to restore the original state)
2. Determine the mounting position of the control board or the electrical cabinet to determine the length of the high temperature wire lead. Be sure to communicate with the factory electrician or foreman to confirm.
3, the coil is measured to measure power, the data must be accurate. To determine the installation power. Can be combined with the factory electrician, this also takes pictures, leaving the original record
4, the circumference of the barrel, determine the size of the insulation cotton, the size of the yellow wax board, the yellow wax board reserved probe hole, the hole size must be accurate, determine the length of each temperature zone, fixed
5. Determine the length of the high temperature wire and wind it. Requires beautiful appearance. neat. Includes pitch size control, tight control. Measure the amount of inductance after winding. Pay attention to the meter range
6, wiring. Confirm the previous circuit breaker ammeter range, too small to be replaced. Test separately, measure voltage, current is normal. Have problems solved one by one, no problem after the whole machine test
7. Finishing and cleaning up the site. Ask for cleanliness.

In order to ensure that the original production process is unchanged after the original equipment is switched to the electromagnetic heating coil, the original operating procedure is unchanged, and the performance difference between the two heating methods is designed. The electromagnetic heater has been reduced by about 30% of power usage, and is heated by electromagnetic heating. Power adjustment and power protection functions are designed on the controller. So the debugging process is quite simple, the user can debug according to the instructions.
 
Product Description

100kW electromagnetic heating controller is specially designed for the application of pipeline heating and plane heating equipment, such as plastic machinery, food machinery, aluminum plastic machine, drum equipment, heating, boiler, oil, and natural gas transmission, etc. With stronger industry pertinence and better energy-saving effect, this product adopts the fifth generation DSP digital processing platform technology of our company, open application structure, wide inductance to adapt to the coil range, through the digital programmable control system, it can realize the special functions of different customers and different occasions, which brings great convenience to customers. It is an electromagnetic heating transformation project and supporting heating equipment Products.

 
Name Performance parameter
rated power Three-phase 100KW
Rated input current 120-150(A)
Rated output current 240-260(A)
Rated voltage frequency AC 380V/50Hz
Voltage adaptation range  constant power output at 300 ~ 400V
Adapt to ambient temperature -20ºC~50ºC
Adapt to environmental humidity ≤95%
Power adjustment range 20% ~ 100% stepless adjustment(That is: adjustment between 0.5 ~ 100KW)
Heat conversion efficiency ≥95%
Effective power ≥98%(Can be customized according to user needs)
working frequency 5~40KHz
Main circuit structure Full bridge series resonance
Control System The DSP-based high-speed automatic phase-locking tracking control system
Application mode Open application platform
monitor Programmable digital display
start time <1S
Instantaneous overcurrent protection time ≤2US
Power overload protection 130% instantaneous protection
Soft start mode Fully electrically isolated soft start heating/stop mode
RS485 communication Modbus RTU standard communication protocol
Support PID adjustment power Identify 0-5V input voltage
Support 0 ~ 1000 ºC load temperature detection Accuracy up to ± 1 ºC
Adaptive coil parameters  Double 35 square line, length 35m, inductance 85 ~ 100uH
Coil to load distance(Thermal insulation thickness) 20-25mm for circle, 15-20mm for the plane, 10-15mm for ellipse and within 10 mm for superellipse
Detailed Photos
 
high frequency induction heater 100kw Electromagnetic Heater Manufacturer Induction Heater

High Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction HeaterHigh Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction HeaterHigh Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction Heater

1, Connect the power supply voltage of the cooling fan, but connect the 220V power when the fan is 220V, and connect the 380V power when the fan is 380V
2, Connected with cooling fan 220V / 380V (depending on the user, generally 380V)
3, When the external cooling fan is DC 24V, this interface is a switch that controls the 24V fan to work or stop. The two ends of the interface are actually the normally closed contact points of the relay output on the motherboard.
4, Dual AC 24V power supply (choose 4 or 5 when making half-bridge)
5, Dual AC 24V power supply (choose 4 or 5 when making half-bridge)
6, Single AC 16V power supply
7, Power indicator (red)
8, Work indicator light, flashing during standby, and always on (green) during work
9, External indicator light, led to the LED interface outside the chassis
10, The soft start interface is connected to the R / s interface outside the chassis (can be set to open or close work through F-20, factory default close work, open stop status
11, Finely adjust the power potentiometer. When there is a large deviation in power, this potentiometer can be adjusted appropriately.
12, 32-bit high-speed DSP processor
13, Externally connected programmable operating display
14, Isolated RS485 communication interface
15, External load temperature detection interface 1, with an accuracy of ± 1 ° C (maximum 150 ° C) single-channel, default 1 is used to measure external working temperature
16, External load temperature detection interface 2, with an accuracy of ± 1 ° C (maximum 150 ° C)
17,Multi-function input interface (set by F-20)
(1)10K input for external connection potentiometer can adjust the power range from 20% to 100%
(2)Externally connected PID input (0 ~ 5V) input
Do infrared thermometer or thermocouple conversion voltage 0 ~ 5V input to achieve the display temperature and control power size (up to 1000ºC can be measured and displayed)
18, Connect the high-frequency Mutual inductor and pay attention to the direction. If the direction is reversed, the power is very small
19, IGBT module drive (when doing half-bridge, choose 19, 20 or 23, 24)
20, IGBT module drive (when doing half-bridge, choose 19, 20 or 23, 24)
21, Connected to high voltage DC bus
22, IGBT temperature sensor interface
23, IGBT module drive (when doing half-bridge, choose 19, 20 or 23, 24)
24, IGBT module drive (when doing half-bridge, choose 19, 20 or 23, 24)
25, Connected to high voltage DC bus
26,RS485 communication interface, connect A ,B
27, Externally connected K-type thermocouple
28, Externally connected 12V relay drives other required loads, synchronized with the fan start/stop of the machine

High Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction HeaterHigh Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction HeaterHigh Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction HeaterHigh Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction Heater
 High Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction HeaterHigh Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction HeaterHigh Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction HeaterHigh Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction HeaterHigh Frequency Induction Heater 100kw Electromagnetic Heater Manufacturer Induction Heater
FAQ

Q: Where is your factory?

A: Located in Foshan city, China.

Q: Are you a trading company or manufacturer?
A: We are a factory.

Q: How long is your delivery time?
A: Generally it is 10 days if the goods are in stock. or it is 40 days if the goods are not in stock, it is according to quantity.

Q: What are your terms of payment?
A: Payment:30% T/T in advance, Pay in full before shipment.

Q: Can I do a customized design? Such as printing logo, change color, material, size, structure, and shape, etc...?
A: Yes, both OEM and ODM services are offered.  can be done as your request. Pls, contact us for more detail.

Q: What other products does the company have?
A:Electromagnetic control cabinet, electromagnetic steam generator, Electromagnetic hot blast furnace

 
Why Choose us?

1, The world-famous brand Infineon IGBT inverter module is used to ensure the stability of the product.

2, a High-speed DSP phase-shifting algorithm is used, and each output cycle is precisely calculated to achieve optimal energy-saving purposes.
3, Magnetically isolated drive technology solves the interference problem caused by the optical drive.
4, strong environmental adaptability, can be used in harsh environments;
5, The system control power supply adopts multi-level EMI suppression to ensure the best quality power supply under harsh power supply conditions.
6, strong anti-interference ability, up to more than 50MW combination of parallel work and reliable operation.
7. Coil to ground protection function. When the coil is broken or the coil is shorted to ground, it can effectively protect the whole system and ensure safe use.
8. It can be customized by water cooling and air cooling, and the cooling fan is a high-speed dc fan to protect the controller cooling system
9. The incoming and outgoing wires of the power supply use copper bar structure and pure copper high-current terminals to ensure that the copper bars and terminals do not generate heat when they are overworked.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier